| Component / Spare Part | Estimated Cost (โน) | Warranty Coverage | Action |
|---|---|---|---|
| ๐ง Daikin Genuine Inverter Outdoor Main PCB | โน2,800 - โน5,800 | 1 Year OEM Warranty | Check Stock |
| ๐ง Daikin Electronic Expansion Valve (EEV) Stepper Coil | โน1,450 - โน2,400 | 1 Year OEM Warranty | Check Stock |
| ๐ง Daikin Swing Compressor Dual Rotary (1.5 TR) | โน7,500 - โน12,500 | 5 Years Compressor Warranty | Check Stock |
| ๐ง Daikin BLDC Blower Motor (Indoor/Outdoor) | โน1,850 - โน3,200 | 1 Year Warranty | Check Stock |
| ๐ง Daikin Dual Thermistor Sensor Set (Room & Coil) | โน650 - โน1,150 | 6 Months Warranty | Check Stock |
| ๐ง Daikin Titanium Apatite Deodorizing Air Filter | โน450 - โน850 | Genuine OEM Part | Check Stock |
Daikin Diagnostic Error Codes Table
| Code | Reported Symptom / Diagnostic Failure | Certified Engineering Resolution |
|---|---|---|
| U4 | Communication error between indoor and outdoor units | Verify 3-wire signal transmission voltage (should pulse 0-55V DC). Check outdoor surge fuse and optical couplers on main PCB. |
| L5 | Inverter compressor instantaneous overcurrent (IPM trip) | Check compressor UVW winding resistance (balanced 0.8-1.5 ohms). Check IPM thermal paste and replace IPM module if shorted. |
| A6 | Indoor fan motor overload or lock condition | Inspect cross-flow blower wheel for foreign debris, test BLDC Hall sensor feedback pulses, replace fan motor if locked. |
| C9 | Indoor return air thermistor open or short circuit | Measure sensor resistance (20k ohm at 25ยฐC). Verify wiring socket harness; replace thermistor probe. |
| E7 | Outdoor propeller fan motor overload or locked rotor | Check fan blade clearance, verify 310V DC bus voltage to outdoor fan motor, replace motor if internal drive IC failed. |
| J3 | Compressor discharge pipe thermistor malfunction | Measure sensor resistance (typically 50k-200k ohm depending on temp). Replace discharge probe if open-circuited. |
| F3 | Abnormal discharge pipe temperature (>115ยฐC overheat) | Indicates severe refrigerant shortage or EEV restriction. Perform nitrogen leak check, vacuum, and recharge virgin R32/R410A. |
Frequently Asked Questions โ Daikin in Commerzone IT Park Yerwada
How fast can a certified Daikin technician reach Commerzone IT Park Yerwada?
Our emergency technician mobile vans are strategically deployed across Commerzone IT Park Yerwada corridors. We guarantee doorstep arrival within <25 min for breakdown calls, equipped with digital diagnostic tools and genuine parts.
Do you use 100% genuine OEM spare parts for Daikin in Commerzone IT Park Yerwada?
Yes. Every replacement inverter PCB, compressor, capacitor, sensor, or motor supplied by our Commerzone IT Park Yerwada Daikin center is a factory-certified genuine part backed by up to 1 year warranty.
Can you repair Daikin Inverter AC PCB boards on-site in Commerzone IT Park Yerwada?
Yes, our mobile vans carry component-level diagnostic testers. Minor relay and fuse faults are fixed on-site in Commerzone IT Park Yerwada. Complex IPM micro-soldering is completed at our Wagholi lab with guaranteed 24-hour turnaround.